Eaton Managed G3 24 Way 20 x C13, 4 x C19 IEC Managed PDU, IEC C20 Plug

Eaton Managed G3 24 Way 20 x C13, 4 x C19 IEC Managed PDU, IEC C20 Plug
search
  • Eaton Managed G3 24 Way 20 x C13, 4 x C19 IEC Managed PDU, IEC C20 Plug
  • Eaton Managed G3 24 Way 20 x C13, 4 x C19 IEC Managed PDU, IEC C20 Plug

The Eaton ePDU G3 Managed PDU with a 16A 1phase input, C20 power cord, 20xC13 and 4xC19 outlets with switched control for outlet rebooting and sequential start-ups across A and B feeds. The G3 ePDU has a menu driven pixel display for easy setup, trouble shooting and access to status information. The power distribution unit provides highly accurate power measurements within +/-1% for revenue grade power monitoring and allows effective input power and outlet power measurements. The monitoring module can be hot-swapped without a server rack power down. Up to 3 sensors per rack PDU can be daisy-chained with each sensor providing 1 environmental probe, 1 humidity probe and 2 dry contacts. Up to eight ePDUs ca be daisy-chained from one IP address.

Phase: Single-phase
Nominal power: 3.84 kW
Nominal current: 16A
Input: C20 coupler
Output: (20) C13 & (4) C19

  • Outlet sockets with dual built-in security mechanism eGrip and P-Lock
  • Colour-coded outlet and branch circuits for simple load balancing
  • 60°C operating temperature
  • Universal rack mounting system (button and clip feet)
  • Alternating phase per sections (3Phase 32A PDU only)
  • Outlet sockets with dual built-in security mechanism eGrip and P-Lock
  • Colour-coded outlet and branch circuits for simple load balancing
  • 60°C operating temperature
  • Universal rack mounting system (button and clip feet)
  • Hot-Swap Control module with Advanced LCD + Optional Temp/Humidity sensor
  • ±1% IEC Class 1 Billing Grade Accuracy for V, W, A and kWh & Cisco EnergyWise compliant
  • Phase Metering, Circuit Breaker Current Metering and Input Metering
  • Daisy-Chain up to 8 ePDUs, reduce network infrastructure costs
  • Power chain monitoring and real time datacentre via the Eaton Intelligent Power Manager
  • Protocols and standards include HTTPS, SSL, Telnet, FTP, SNMP, SMTP, DHCP, LDAP, RADIUS, DHCP 66/67 for mass configuration
  • Circuit Breaker Status Monitoring
  • Outlet and IT Equipment Metering across A and B feed
  • Level 3 PUE measurements
  • Turn off unused outlets to control commissioning
  • Outlet and IT Equipment Switching/reboot /sequencing across A and B feed

Vertical mounting units (0U) include both rear and side button mounting system and Eaton’s patented variable clip feet. Horizontal units (1U/2U) come with rack ear support.