Eaton Metered Input G3 16 Way C13 IEC, C14 Plug Vertical PDU

Eaton Metered Input G3 16 Way C13 IEC, C14 Plug Vertical PDU
search
  • Eaton Metered Input G3 16 Way C13 IEC, C14 Plug Vertical PDU
  • Eaton Metered Input G3 16 Way C13 IEC, C14 Plug Vertical PDU
  • Eaton Metered Input G3 16 Way C13 IEC, C14 Plug Vertical PDU

The Eaton EMIB03 16-Way 24U Vertical Rackmount Metered Input PDU allows metering to the branch and phase level for effective load balancing, with no switching. The EMIB03 includes IEC Class 1 (1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing V, W, A and kWh, and the ability to daisy chain eight (8) ePDUs to share the same network connection and IP address.

Eaton metered input rack PDUs give you remote monitoring capabilities and provide access to your power data whenever you want it, wherever you are. You also can monitor your critical equipment within each colour-coded outlet section from a single interface and achieve 1% billing-grade accuracy. With all of the features of the basic PDU, 0U, 1U and 2U metered input rack-mount PDUs provide you with the ability to reduce infrastructure costs by daisy-chaining up to eight metered PDUs to share the same network connection and single IP address. The metered input PDU also simplifies load balancing and helps prevent overloads.

Phase: Single-phase
Nominal power: 11kW
Nominal current: 10A
Input: C14 Output: (16) C13

  • Phase Metering, Circuit Breaker Current Metering and Input Metering.
  • Hot-Swap Control module with advanced LCD.
  • Optional Temperature/Humidity sensor (sold separately).
  • Built-in IEC outlet eGrip retention, retains all standard IEC plugs.
  • Built-in outlet P-lock system, locking mechanism with P-lock power cords.
  • Daisy-Chain up to 8 PDUs, reduce network infrastructure costs.
  • Power chain monitoring and real time intelligence on your data centre, via Eaton Intelligent Power Manager (sold separately).
  • 60°C Operating temperature.
  • Colour-coded outlet and branch circuits for simple load balancing.
  • Hydraulic–Magnetic Circuit Breakers with accidental trip protection.
  • Universal mounting system: Button mounting on rear and side + variable mounting system.
Download PDF (1.27MB) Eaton G3 ePDU